l  Serial & Data Packing Settings: l  “Serial” Port   n   Baud : serial port baud rate, supports 1200~38400 bps n   Data Format: [P][D][S] u   [P] Parity Check Bit: supports ”N”(None), “O”(Odd), ”E”(Even) u   [D] Data Bit: data bit transmit length supports ”7”, ”8” u   [S] Stop Bit: supports ”1”, ”2” n   Flow Control: supports ”NONE”, “TRS/CTS”, “XON/XOFF” n   Interface: RS-232 Only    l  “Data Packing” The data packing algorithm minimizes the packet count on the network and is    especially useful in applications in a routed Wide Area Network (WAN). n   Length: Determine the transmission of the data by the data length sent by   eCOV-110 n   Timeout: Defines the  value  of  timing  which  does  not  receive  data  from  serial           port, then it sends out data packing via Internet. n   Delimiter: You can enter up to two characters in hexadecimal representation in    the parameters "Delimiter." If a character received on the serial line matches one of these characters, it is sent immediately, along with any awaiting characters, to the TCP connection. For example, the data is sent when”0d0a” is received (the  Enter key on keyboard). u   Notes: But if there are successively entering a great quantity of data into the RS-232 port of eCOV-110, when the input queue are over 2K byte, this “Delimiter” function will be ignored. Thus eCOV-110 will sent all the queue data once to the Network in order to ensure the reliability of data transmission. l  “Network Setting” n   IP Mode:  IP address retrieve method, supports DHCP(DHCP Client) and Static  
mode. If you set to DHCP Mode and could not retrieve IP address from DHCP    server, the network will reset the setting to Static IP mode. n   IP Address: The IP address must be set to a unique value in your network. n   Subnet Mask: A subnet mask defines the number of bits taken from the IP    address that assigned for the host section. n   Gateway: The Gateway IP address allows communication to other LAN   segments. This should be the IP address of the router connected to the same LAN segment as the eCOV-110 unit. n   MAC Address: Display the current MAC address. n   Ethernet Status: Display the current network connection status. 2.2.3.   Operating Modes Settings l  TCP-IP-Network Settings n   OP Mode: TCP transmission mode, you can select TCP Server(default), or TCP Client, UDP TCP Server Mode: Awaiting for   remote connection attempts. -   Listen Port: The TCP port # for    remote connection (Note: It is not recommended to use any port # below 10000)     -   Timeout: Connection interrupt time
TCP Client Mode: Attempts to    connect with the remote TCP server. -    Remote Port: The remote TCP server port # to be connected by the client. -    Connect At: Choose when the TCP connection to be occurred. You can    select”Startup” or “Serial data in”. -    Remote IP:  The remote TCP server’s IP Address to be connected     by the client. -    Timeout: Connection interrupt time UDP Mode:   -    Remote IP:  The IP address for remote connection. -    Remote Port: The UDP port for remote connection. -    Local Port:  The Local port for remote connection. u   Notes for Timeout function: When the serial port has not received any data    within the predefined time frame (Timeout), the TCP connection will be   interrupted and back to its default status waiting for reconnection. 2.2.4.    Access Control Settings l  Ethernet IP Filtering This setting is to define or restrict the specific IP address that can have TCP connection to eCOV-110.
n   Start IP:  The start number of IP address range that can be connected with    eCOV-110. n   End IP:  The end number of IP address range that can be connected with    eCOV-110. l  Password Setting Setting the configuration password prevents unauthorized access of the setup menu    and harmful modification to the module. n   Old Password: Current password value, if no setting was made, it remains null. n   New Password: Newly created password value, to clear old value just input   nothing. n   Re-Type Again: Re-enter the newly created password value to prevent any    mistakes or unintentional error, to clear old value just input nothing. ** If the password is lost or forgotten, please use the Serial Command to   reset to factory default value and clear the password (please refer to    section 4 for detailed description).   2.2.5.    Enable and save the settings l  Save to Module Save all the newly changed settings to eCOV-110, and only after the “Reboot    Module” is executed or restart the eCOV-110 power, the settings will be taken effect. l  Export Save the current settings to file, can also combine with the “Import” function for batch    setting changes for OEM manufacturer or end users. l  Import Download the setting file created by the ”Save to File” function to eCOV-110 for   batch setting changes for OEM manufacturer or end users. l  Abort
Exit the setting screen and discard any setting changes without saving. 2.3.“Monitor” function Click “Monitor” function, ”monitor start” will show on the below  window of the main menu, if you click “Exit” function, then ending this “Monitor” function. 2.3.1     eCOV-110 network disconnect detecting When network disconnect detecting, the eCOV-110 becomes red in main table. Possible reason: Ø  eCOV-110 power off. Ø  eCOV-110 physically disconnect with the remote TCP server. 2.3.2     eCOV-110 connect again: When eCOV-110 connect again, the eCOV-110 resumes black in main table.