B. Commands list
EOT
SOH COMMAND
ETB
1. Set Baud Rate
COMMAND: B
COMPUTER:EOT SOH 'B' 'BAUD RATE' 'N'
ETB
ASCII (04H) (01H)(42H) (31H~36H)
(4EH)(17H)
Byte
1 1
1 1
1 1
DISPLAY: ACK
(or NACK if failed)
ASCII (06H)
(15H)
Byte
1 1
Note: Baud rates
31H : 9600
32H : 4800
33H : 2400
34H : 1200
35H : 600
36H : 300
End of Transmission Block
(17 Hex)
See Command list
Start of Heading
(01 Hex)
(04 Hex)
2. Save the current view message
3. Set cursor position
(Save Demo view data)
COMMAND: S
COMPUTER:EOT SOH 'S'
'Layer' ETB
ASCII(04H)(01H)(53H)(31H~36H)(17H)
Byte 1
1 1
1 1
DISPLAY: ACK
(or NACK if failed)
ASCII (06H)
(15H)
Byte
1 1
COMMAND: P
COMPUTER: EOT SOH
'P' 'Position'
ETB
ASCII (04H) (01H) (50H) (31H~58H)
(17H)
Byte 1
1 1
1 1
DISPLAY: ACK
(or NACK if failed)
ASCII (06H)
(15H)
Byte 1
1
Note: The cursor can be set to the
position from 1 to 40
Position 1 means the upper left corner
position.
Position 20 means the upper right corner
position.
Position 21 means the lower left corner
position.
Position 40 means the lower right corner
position.
-13-