l Serial
& Data Packing Settings:
l “Serial”
Port
n Baud
: serial port baud rate, supports 1200~38400 bps
n Data
Format: [P][D][S]
u [P]
Parity Check Bit: supports ”N”(None), “O”(Odd), ”E”(Even)
u [D]
Data Bit: data bit transmit length supports ”7”, ”8”
u [S]
Stop Bit: supports ”1”, ”2”
n Flow
Control: supports ”NONE”, “TRS/CTS”, “XON/XOFF”
n Interface:
RS-232 Only
l “Data
Packing”
The data packing algorithm minimizes the packet
count on the network and is
especially useful in applications in a routed
Wide Area Network (WAN).
n Length:
Determine the transmission of the data by the data length sent by
eCOV-110
n Timeout:
Defines the value of timing which does not receive data from serial
port, then it sends out data packing via
Internet.
n Delimiter:
You can enter up to two characters in hexadecimal representation in
the parameters "Delimiter." If a character
received on the serial line
matches one of these characters, it is sent
immediately, along with
any awaiting characters, to the TCP connection.
For example, the
data is sent when”0d0a” is received (the Enter
key on keyboard).
u Notes:
But if there are successively entering a great quantity of data into
the RS-232 port of eCOV-110, when the input
queue are over 2K byte, this
“Delimiter” function will be ignored. Thus
eCOV-110 will sent all the
queue data once to the Network in order to
ensure the reliability of data
transmission.
l “Network
Setting”
n IP
Mode: IP address retrieve method, supports DHCP(DHCP Client) and Static
mode. If you set to DHCP Mode and could not
retrieve IP address from DHCP
server, the network will reset the setting to
Static IP mode.
n IP
Address: The IP address must be set to a unique value in your network.
n Subnet
Mask: A subnet mask defines the number of bits taken from the IP
address that assigned for the host section.
n Gateway:
The Gateway IP address allows communication to other LAN
segments. This should be the IP address of the
router connected to the
same LAN segment as the eCOV-110 unit.
n MAC
Address: Display the current MAC address.
n Ethernet
Status: Display the current network connection status.
2.2.3. Operating
Modes Settings
l TCP-IP-Network
Settings
n OP
Mode: TCP transmission mode, you can select TCP Server(default), or TCP
Client, UDP
TCP Server Mode:
Awaiting for
remote connection attempts.
- Listen Port: The
TCP port # for
remote connection
(Note: It is not recommended to use
any port # below 10000)
- Timeout:
Connection interrupt time
TCP Client Mode:
Attempts to
connect with the remote TCP server.
- Remote Port: The
remote TCP
server port # to be connected by the
client.
- Connect At:
Choose when the TCP
connection to be occurred. You can
select”Startup” or “Serial data in”.
- Remote IP: The
remote TCP
server’s IP Address to be connected
by the client.
- Timeout: Connection interrupt
time
UDP Mode:
- Remote
IP: The IP address for
remote connection.
- Remote Port:
The UDP port for
remote connection.
- Local Port:
The Local port for
remote connection.
u Notes
for Timeout function: When the serial port has not received any data
within the predefined time frame (Timeout), the
TCP connection will be
interrupted and back to its default status
waiting for reconnection.
2.2.4. Access
Control Settings
l Ethernet
IP Filtering
This setting is to define or restrict the
specific IP address that can have TCP
connection to eCOV-110.
n Start
IP: The start number of IP address range that can be connected with
eCOV-110.
n End
IP: The end number of IP address range that can be connected with
eCOV-110.
l Password
Setting
Setting the configuration password prevents
unauthorized access of the setup menu
and harmful modification to the module.
n Old
Password: Current password value, if no setting was made, it remains null.
n New
Password: Newly created password value, to clear old value just input
nothing.
n Re-Type
Again: Re-enter the newly created password value to prevent any
mistakes or unintentional error, to clear old
value just input nothing.
** If the password is lost or forgotten, please
use the Serial Command to
reset to factory default value and clear the
password (please refer to
section 4 for detailed description).
2.2.5. Enable and
save the settings
l Save
to Module
Save all the newly changed settings to
eCOV-110, and only after the “Reboot
Module” is executed or restart the eCOV-110
power, the settings will be taken effect.
l Export
Save the current settings to file, can also
combine with the “Import” function for batch
setting changes for OEM manufacturer or end
users.
l Import
Download the setting file created by the ”Save
to File” function to eCOV-110 for
batch setting changes for OEM manufacturer or
end users.
l Abort
Exit the setting screen and discard any setting
changes without saving.
2.3.“Monitor” function
Click “Monitor” function, ”monitor start” will
show on the below window of the main menu,
if you click “Exit” function, then ending this
“Monitor” function.
2.3.1 eCOV-110
network disconnect detecting
When network disconnect detecting, the eCOV-110
becomes red in main table.
Possible reason:
Ø eCOV-110
power off.
Ø eCOV-110
physically disconnect with the remote TCP server.
2.3.2 eCOV-110
connect again:
When eCOV-110 connect again, the eCOV-110
resumes black in main table.